ADR-0023: Paramset Consistency Checker

Status

Implemented

Date

2026-02-09

Context

The HmIPServer Staleness Problem

The Homematic XML-RPC API exposes two complementary endpoints for device configuration:

  • getParamsetDescription() returns the schema - which parameters a device channel supports, their types, ranges, and access flags.
  • getParamset() returns the values - the actual stored configuration data for those parameters.

These two endpoints should always be consistent: every parameter described in the schema should have a corresponding value in the data. However, a bug in the HmIPServer (crRFD), documented by jmaus (RaspberryMatic developer), breaks this invariant.

After a device firmware update, the HmIPServer updates its schema (.dev files) to reflect new parameters but does not re-read the actual parameter values from the device. The result is a phantom parameter - described in the schema, absent from the data.

Example: An HmIP-FSM16 with firmware 1.22.8 introduces CHANNEL_OPERATION_MODE on channel 5 (to switch between consumption and feed-in metering). The schema correctly lists the parameter, but the data endpoint returns it as if it doesn't exist. The parameter is invisible to all clients.

Impact on aiohomematic

aiohomematic creates data points based on the schema (getParamsetDescription()). When a parameter exists in the schema but not in the data, the resulting data point is technically valid but functionally broken - it has no value, cannot be read, and cannot be written. This manifests as:

  1. Phantom entities in Home Assistant that appear in the UI but always show "unavailable" or stale defaults.
  2. Silent failure - no indication to the user why a feature that should be available after a firmware update is missing.
  3. Recurring support requests across multiple device types: HmIP-FSM16, HmIP-SPI, HmIP-SMO, HmIPW-WTH, HMIP-SWDO, and potentially others.

What We Can and Cannot Do

Only eQ-3 can fix the root cause (the HmIPServer should re-read device parameters after firmware updates). The only user-side remedy is a factory reset of the affected device on the CCU, which forces the HmIPServer to re-read all parameters from scratch.

aiohomematic's role is limited to detection and notification.

Decision

Add a consistency check that compares schema (cached getParamsetDescription()) against data (getParamset() via RPC) for MASTER paramsets after device creation, and surfaces discrepancies to the user via the existing reporting infrastructure.

Core Concept: Schema-vs-Data Comparison

The check exploits a simple invariant:

For every parameter P in getParamsetDescription(channel, MASTER)
  where P.OPERATIONS > 0:
    P must also appear as a key in getParamset(channel, MASTER)

A violation of this invariant indicates the HmIPServer staleness bug.

The OPERATIONS > 0 filter is essential: parameters with OPERATIONS = 0 are internal metadata that may legitimately be absent from getParamset() responses.

Design Principles

  1. Detection only - We cannot repair the data; we can only tell the user what's wrong and how to fix it (factory reset).

  2. Non-blocking - The check runs as a background task after device creation. Devices are immediately available; the consistency check is purely advisory and must never delay startup or block the device creation pipeline.

  3. MASTER paramsets only - The bug manifests exclusively in MASTER (configuration) paramsets. VALUES paramsets are volatile runtime data and are not affected.

  4. HmIP scope only - The HmIPServer (crRFD) is the only backend component affected. BidCos-RF devices (managed by rfd) and Homegear devices are not subject to this bug. The check filters by ProductGroup.HMIP and ProductGroup.HMIPW.

  5. Dual reporting - Discrepancies are reported through two channels:

  6. IncidentStore (persistent diagnostics, survives restarts, visible in diagnostics export)

  7. IntegrationIssue via SystemStatusChangedEvent (surfaced as HA Repair issue, immediately actionable by the user)

  8. Idempotent - Running the check multiple times with unchanged data produces identical results.

When the Check Runs

The check is triggered after create_devices() completes during the _add_new_devices() flow. This is the natural point: paramset descriptions are freshly cached, devices are just created, and the schema-data comparison can be performed while the system is already communicating with the CCU.

_add_new_devices()
  ├─ fetch paramset descriptions
  ├─ create_devices()          ← Devices available immediately
  └─ schedule background task  ← Consistency check (non-blocking)
      └─ for each HmIP device + channel:
           compare schema keys vs. data keys

Reporting Strategy

The checker aggregates all missing parameters per device (across all channels) into a single report. This avoids noise: a device with 3 missing parameters across 2 channels produces one incident and one integration issue, not six.

Missing parameters are identified in {channel_address}:{parameter_name} format (e.g., VCU0000001:5:CHANNEL_OPERATION_MODE) to allow precise attribution.

Error Handling Philosophy

The consistency check is advisory - it must never cause harm:

  • If a device is temporarily unreachable during get_paramset(), the channel is silently skipped. No false positive is generated.
  • If the IncidentRecorderProtocol is unavailable (optional dependency), the check still reports via IntegrationIssue.
  • If no inconsistencies are found, nothing is reported (no "all clear" noise).

Architecture

Data Flow

┌─────────────────────────┐     ┌──────────────────────┐
│ ParamsetDescription     │     │ InterfaceClient      │
│ Registry (cached)       │     │ get_paramset()       │
│                         │     │                      │
│ "What SHOULD exist"     │     │ "What DOES exist"    │
└────────────┬────────────┘     └──────────┬───────────┘
             │ expected params             │ actual params
             └──────────┬─────────────────-┘
                        │ set difference
                ┌───────────────┐
                │ Missing any?  │
                └───────┬───────┘
                        │ yes
             ┌──────────┴──────────┐
             ▼                     ▼
  ┌──────────────────┐  ┌────────────────────┐
  │  IncidentStore   │  │  SystemStatus      │
  │  (diagnostics)   │  │  ChangedEvent      │
  │                  │  │  (IntegrationIssue) │
  └──────────────────┘  └─────────┬──────────┘
                        ┌────────────────────┐
                        │  Home Assistant     │
                        │  Repair Issue       │
                        └────────────────────┘

Integration Points

The checker integrates into existing infrastructure without introducing new abstractions:

  • DeviceCoordinator hosts the check logic (consistent with its role as device lifecycle manager).
  • IncidentRecorderProtocol provides persistent diagnostics recording (optional dependency via DI).
  • SystemStatusChangedEvent + IntegrationIssue is the established pattern for surfacing actionable issues to Home Assistant (same as PING_PONG_MISMATCH and INCOMPLETE_DEVICE_DATA).
  • i18n.tr() provides localized log messages (English and German).

Risks and Mitigations

Risk Likelihood Impact Mitigation
RPC calls slow startup Low Low Background task; devices available before check runs
Device unreachable mid-check Medium Low Per-channel try/except; other devices still checked
False positives Low Medium OPERATIONS > 0 filter; HmIP-only scope
CCU rate limiting Low Low Existing request coalescing handles deduplication
User fatigue from warnings Medium Low WARNING severity; includes actionable fix (factory reset)

Deferred Work

CONFIG_PENDING Re-Check

After a factory reset, the CCU sends CONFIG_PENDING = False. This would be an ideal trigger to re-verify that the inconsistency is resolved. Deferred because:

  • The initial device creation check covers the primary discovery scenario
  • CONFIG_PENDING handling requires model-layer changes
  • Can be added incrementally without breaking changes

Periodic Re-Verification

A periodic background check (e.g., weekly) could catch inconsistencies that develop after initial device creation (e.g., firmware updates during runtime). Deferred because the startup check covers the most important case and periodic checks add RPC overhead.

Alternatives Considered

1. Hub-Level Diagnostic Sensor

Expose a sensor with the count of inconsistent devices. Rejected because it provides no device-specific information, requires periodic polling, and adds permanent UI clutter for a condition that affects few users.

2. Automatic Paramset Repair

Call putParamset() with default values for missing parameters. Rejected because it could cause unintended device behavior, may not work (HmIPServer might reject writes to parameters it doesn't track), and violates the detection-only principle.

3. Startup-Blocking Validation

Run the check synchronously during startup and refuse to create data points for inconsistent parameters. Rejected because it delays device availability and removes entities that are technically valid (they just have no current value).

References