Short description of calculated sensors¶
Operating Voltage Level¶
requires: operating voltage, max voltage(battery voltage*qty), min voltage (low bat limit default)
Calculated sensor to define the left over capacity within the usable voltage range.
Climate sensors¶
Apparent Temperature (Feels like)¶
requires: temperature, humidity, wind speed
Calculated sensor that displays a perceived temperature using temperature, humidity and wind speed.
Dew Point¶
requires: temperature, humidity
The temperature, with constant pressure and water-vapour content, to which air must be cooled for saturation to occur.
Dew Point Spread¶
requires: temperature, humidity
The difference between current air temperature and dew point. Specifies the safety margin against condensation(K).
• Spread < 2K → critical (condenser danger) • Spread 2–4K → caution, high humidity • Spread > 5 K → safe area
Enthalphy¶
requires: temperature, humidity, air pressure (used default is 1013.25 hPa)
The specific enthalpy of humid air in kJ/kg (relative to dry air). Relevant It is important when calculating, for example, heat recovery or ventilation efficiency.
Frost Point¶
requires: temperature, humidity
The temperature to which a sample of air must be cooled, at constant pressure and humidity, to reach saturation with respect to ice.
Vapor Concentration (Absolute Humidity)¶
requires: temperature, humidity
The vapor concentration or absolute humidity of a mixture of water vapor and dry air is defined as the ratio of the mass of water vapor Mw to the volume V occupied by the mixture.
Dv = Mw / V expressed in g/m3