Alarm engine: researched assumptions (§18 grounding)

This document records what web/manual/forum research established for the open questions in docs/alarm-concept.md §18, the implementation assumptions the alarm engine derives from that research, and the confidence per claim ([confirmed] / [likely] / [contested] / [unknown]). It complements — never replaces — the supervised live tests §18 calls out, which remain parked until the operator schedules them and names the target device (see CLAUDE.md, "Live-CCU writes need explicit user approval").


Q1 — ASIR/ASIR-2/ASIR-O firmware duration cap (§18 Q1)

Established

Implementation assumption: no device- or firmware-side duration cap is a safety backstop, confirmed or not. The engine's own stop watchdog is the sole authoritative bound: every siren TurnOn unconditionally schedules an engine-side stop at configured-duration + safety margin, sized to comfortably exceed worst-case duty-cycle retry latency (~2×40s under this repo's current retry defaults); an overrun is logged/alerted, never silently tolerated.

Still needs live verification: whether indoor ASIR/ASIR-2 firmware silently truncates or extends configured durations on the operator's actual firmware, and whether ASIR-O firmware enforces a hard 3-minute ceiling vs. a configurable range max. → §18 Q1 supervised live test.


Q2 — DURATION_VALUE = 0 semantics (§18 Q2)

Established

  • [unknown] No source states or demonstrates what DURATION_VALUE = 0 does on the device with a tone/optical signal selected — no-op vs. infinite sounding vs. something else is undocumented everywhere searched.
  • [confirmed] Community practice and the aiohomematic reference implementation avoid DURATION_VALUE = 0 entirely: to silence a siren, both community scripts and aiohomematic's turn_off() rewrite ACOUSTIC_ALARM_SELECTION/OPTICAL_ALARM_SELECTION to disable plus a concrete non-zero duration pair. https://forum.iobroker.net/topic/7897/gel%C3%B6st-homeatic-ip-alarm-siren-%C3%BCber-script-steuern
  • [confirmed] All four paramset values (ACOUSTIC_ALARM_SELECTION, OPTICAL_ALARM_SELECTION, DURATION_UNIT, DURATION_VALUE) must be written together; partial writes are widely reported ignored, or as causing the device to re-execute a previous pattern. https://homematic-forum.de/forum/viewtopic.php?t=76596
  • [likely] Direct writes to ACOUSTIC_ALARM_ACTIVE/OPTICAL_ALARM_ACTIVE are rejected with an XML-RPC error; at least one first-hand report confirms this. https://github.com/SukramJ/aiohomematic/discussions/734

Implementation assumption: the engine never emits DURATION_VALUE = 0; every TurnOn writes a concrete positive duration pair, and every stop is one atomic putParamset carrying all four parameters, matching internal/model/custom/siren/siren.go's existing TurnOff path, dispatched at CommandPriority.Critical. The stop watchdog — not DURATION_VALUE semantics — is the sole authoritative bound. ACOUSTIC_ALARM_ACTIVE/OPTICAL_ALARM_ACTIVE are read-only feedback; the engine never writes them.

Still needs live verification: the actual device behavior for DURATION_VALUE = 0 with a tone selected. Since the engine never relies on it, this is informational only — it would help the reconciliation logic reason about a peer-caused zero-duration write, not change the engine's own write path. → §18 Q2 supervised live test.


Established: research here is thin — neither the ASIR nor SWSD research pass produced a source that directly tests whether CCU firmware accepts a sensor→ASIR :3 LINK-paramset direct link, or specifically whether KRCA/SWSD pairings are refused. The one adjacent signal:

Implementation assumption: with no evidence either way, the engine does not assume Tier C (always-armed direct links) is viable on HmIP firmware; Tier C ships gated behind the §18 Q3 live test (feature-catalogue row 24, P3). The adjacent signal (community preference for virtual-button links for siren reliability) does not resolve sensor→ASIR pairing acceptance, so it is not acted on architecturally.

Still needs live verification: everything — whether CCU firmware accepts a sensor→ASIR :3 direct link at all, and whether KRCA/SWSD pairings are refused. Untouched by the current research pass. → §18 Q3 supervised live test.


Q4 — WKP integration depth (§18 Q4)

Established

  • [confirmed] Wire layout: channel :0 (MAINTENANCE) carries CODE_ID, CODE_STATE, BLOCKED_TEMPORARY, BLOCKED_PERMANENT, SABOTAGE(_STICKY), USER_AUTHORIZATION_01..08, CLEAR_ERROR; channels :1-:16 are 8 ACCESS_TRANSCEIVER pairs (odd = PRESS_LOCK + NUMERIC_PIN_CODE, even = PRESS_UNLOCK). https://raw.githubusercontent.com/SukramJ/pydevccu/master/pydevccu/device_descriptions/HmIP-WKP.json
  • [confirmed] PRESS_LOCK/PRESS_UNLOCK are declared OPERATIONS=4 (EVENT only) — momentary push events, never polled/persisted state.
  • [confirmed] By default PRESS_LOCK/PRESS_UNLOCK value-changes are frequently NOT forwarded via XML-RPC until CCU-side interest is established — typically a dummy WebUI Program referencing the channel. https://github.com/jens-maus/RaspberryMatic/issues/1846
  • [likely] Each ACCESS_TRANSCEIVER channel exposes a writable MASTER param ABORT_EVENT_SENDING_CHANNELS (0-65535, default 1), plausibly the switch behind that quirk, clearable via putParamset instead of the WebUI-program workaround.
  • [likely] CODE_ID emits sentinel values outside its declared paramsetDescription MAX=8 (idle/unknown reports CODE_ID=32); the same bug class is confirmed and patched for the sibling HmIP-FWI (CODE_ID=31 vs. declared MAX=20/21). https://forum.iobroker.net/topic/55966/hmip-fwi-code_id-has-value-31-greater-than-max-20
  • [confirmed] CODE_ID/CODE_STATE alone cannot disambiguate Lock vs. Unlock intent — only the separate per-channel-pair PRESS_LOCK/PRESS_UNLOCK events carry that.
  • [confirmed] The PIN is stored as NUMERIC_PIN_CODE — an ordinary MASTER paramset STRING (8-digit pattern), OPERATIONS=3 (READ+WRITE) — technically writable via any client with device access; the WebUI/App is a friendly wrapper, not a protocol-level exclusivity gate.
  • [confirmed] Resetting Sabotage/Temporary/Permanent lockouts requires two steps: a WebUI "Sperren zurücksetzen" action, then physically confirming on the device's "Verriegeln" button — the WebUI action alone is insufficient. https://technikkram.net/blog/2022/05/29/quicktipp-keypad-hmip-wkp-servicemeldungen-zuruecksetzen/
  • [contested] Temporary-lockout base delay: 30s per the CCU3 FAQ PDF vs. 15s per the newer (v1.1, 01/2023) App user manual. https://homematic-ip.com/sites/default/files/downloads/faq-servicemeldungen-hmip-wkp.pdf

Implementation assumption: the engine correlates CODE_ID (channel :0) with PRESS_LOCK/PRESS_UNLOCK (per channel-pair) by channel-pair-index == CODE_ID and arrival within a short time window, rather than trusting either signal alone; it gates all CODE_ID interpretation on CODE_STATE == KNOWN_CODE_ID_RECEIVED and never validates/clamps CODE_ID against its declared paramsetDescription MAX. At pairing/startup the engine proactively ensures event delivery for channels 1-16 (clearing ABORT_EVENT_SENDING_CHANNELS via putParamset). On-device PIN slots stay independent of engine codes: CODE_ID is an opaque identity token mapped to operator-assigned channel labels ("User N"), never a PIN value. The engine never writes NUMERIC_PIN_CODE, ACCESS_AUTHORIZATION, BLOCKING_*, or CLEAR_ERROR — those stay WebUI/operator-owned. BLOCKED_TEMPORARY/BLOCKED_PERMANENT/SABOTAGE(_STICKY) surface as health/diagnostic signals only.

Still needs live verification: whether CODE_ID/PRESS_LOCK/PRESS_UNLOCK events are reliably delivered out of the box on the operator's actual firmware without the ABORT_EVENT_SENDING_CHANNELS workaround; the real CODE_ID idle sentinel value on the operator's unit; the actual temporary-lockout base delay (30s vs. 15s) — none safe to hard-code from secondhand sources alone.


Q7 — Current-app verification of cited HmIP behaviours (§18 Q7)

Established

  • [confirmed] "Scharfschalten pro" checks the battery state of security sensors and refuses to arm if low; it also blocks arming on open windows/tamper. https://homematic-ip.com/sites/default/files/downloads/homematic-ip-anwenderhandbuch.pdf
  • [likely] The arming-refusal UI names the specific offending sensor by device/room name inline in a "cannot arm" dialog at the moment of the failed attempt.
  • [confirmed] In the current app, tapping "Bestätigen" on a triggered-alarm push disarms the mode, while "Abbrechen" closes the message but leaves the mode active and suppresses further pushes for that episode.
  • [confirmed] This Bestätigen/Abbrechen behavior does not apply to smoke-detector fire alarms — remote deactivation via the app is not offered, for personal-safety reasons; only physical-detector silencing works.
  • [confirmed] The Basis vs. Pro arming-mode distinction is unchanged and applies identically on the HCU1, using the same app flow as the classic Access Point.

Implementation assumption: the concept's citations of pre-HCU manual behaviour are confirmed current as of the 2025-06-05 Anwenderhandbuch — §18 Q7 is resolved by documentation research, no live test needed for these claims. The alarm-engine design avoids the literal "Bestätigen"/"Abbrechen" labels (a documented confusion source) in favor of unambiguous verbs ("Disarm" / "Dismiss (stay armed)"). Fire/smoke hazard detection stays always-live independent of arm state and offers no remote silence/disarm from the app surface, mirroring the confirmed personal-safety invariant.

Still needs live verification: nothing semantic — Q7 closes on documentation alone for the three cited behaviours. Only exact current UI copy/wording (not semantics) would benefit from a screenshot pass against a live HCU1/app pairing, out of scope for engine behaviour.


Q8 — SWSD smoke-detector sounders: self-termination and propagation (§18 Q8)

Established

  • [confirmed] SMOKE_DETECTOR_COMMAND (channel 1) is a 6-value enum including 1=INTRUSION_ALARM_OFF, 2=INTRUSION_ALARM; writing 2 triggers the intrusion sounder, 1 is the documented explicit stop command. https://www.eq-3.de/downloads/download/handbuecher/WebUI_Handbuch_eQ-3.pdf
  • [confirmed] SMOKE_DETECTOR_ALARM_STATUS is a 4-value enum: IDLE_OFF, PRIMARY_ALARM (local smoke), INTRUSION_ALARM (this device commanded as siren), SECONDARY_ALARM (relayed from another grouped device; German UI label "fremdausgelöster Alarm").
  • [likely] Whether a commanded INTRUSION_ALARM self-terminates after a device-side timer is unconfirmed/undocumented; the strongest evidence is a forum thread literally titled "Dauer Einbruchalarm?" with no verified test result — one operator built their own ~3-minute external cutoff for lack of a confirmed answer. https://homematic-forum.de/forum/viewtopic.php?t=41251
  • [contested] A separate thread claims "there is no ALARM_OFF command", contradicting the confirmed enum values above. https://homematic-forum.de/forum/viewtopic.php?t=34685
  • [likely] Commanding INTRUSION_ALARM on one HmIP-SWSD likely propagates by default to every other HmIP-SWSD auto-linked into the same smoke-detector group (up to 40 devices) — unlike real smoke-alarm forwarding, which is gated by a per-device checkbox.
  • [likely] A non-addressed grouped peer reports SECONDARY_ALARM, not INTRUSION_ALARM — that value is reserved for the directly addressed device.
  • [confirmed] Using an HmIP-SWSD as an additional intrusion output measurably shortens its battery life below the rated ~10 years, because the battery is permanently built in and non-user-replaceable; community reports go as low as ~2 years to depletion.

Implementation assumption: HmIP-SWSD is modeled as a "no built-in duration parameter" output class (unlike HmIP-ASIR's DURATION/DURATION_UNIT) — the engine's per-output max-run-time watchdog (S2) is the only bound on how long any SWSD sounds. SMOKE_DETECTOR_COMMAND = INTRUSION_ALARM is treated as a level command with no assumed device-side auto-off and is always paired with the stop watchdog explicitly writing INTRUSION_ALARM_OFF on timer elapse or disarm. Because group-propagation is only "likely," a single INTRUSION_ALARM_OFF write is not trusted to silence a whole group: if the engine tracks per-device alarm state for SWSD outputs, it polls/subscribes SMOKE_DETECTOR_ALARM_STATUS on every grouped SWSD and, on stop, explicitly writes INTRUSION_ALARM_OFF to every device that was ever the addressed target during the episode. The SWSD-as-output driver stays architecturally separate from the SWSD-as-input hazard path — the derived smoke hazard sensor maps only PRIMARY_ALARM/SECONDARY_ALARM, never the commanded INTRUSION_ALARM (feature-catalogue row 8 in docs/alarm-concept.md). The battery-wear caveat is surfaced wherever the SPA offers an SWSD as a candidate output, and SWSD ships as an engine-watchdog-only opt-in, never on by default, until §18 Q8 resolves.

Still needs live verification: whether a commanded INTRUSION_ALARM self-terminates after any device-side timer or sounds indefinitely until INTRUSION_ALARM_OFF, and whether it actually propagates to grouped detectors as SECONDARY_ALARM. Both remain the explicit §18 Q8 gate before smoke sounders can ship on by default. → §18 Q8 supervised live test.


Alarmo / HmIP app design implications

From research_app-alarmo.md, informing UX and phasing beyond the numbered §18 questions:

  • Model arm-refusal on Alarmo's FAILED_TO_ARM event shape (an explicit list of {sensor, name} blocking the attempt) rather than an ambiguous status icon — stronger and more directly confirmed than anything documented for the current HmIP app.
  • [confirmed] The app's "Rauchwarnmelder-Alarm" option is a single global toggle, not configurable per arming mode: enabling it makes all installed smoke detectors sound as an auxiliary siren on intrusion, separate from each detector's own always-on fire detection. Loom's per-mode assignment (docs/alarm-concept.md §7) is therefore a deliberate superset of the app's capability, not parity: the global behaviour is expressible (assign to every mode), the reverse is not. The concept's recommended default — full protection only — stands.
  • Ship a per-sensor debounce/hold-time (delay_on-equivalent) and a per-sensor entry-delay override as first-class MASTER-editable fields — both are validated, long-requested, now-shipped Alarmo patterns (v1.10.16, closing issue #1289) worth adopting directly.
  • No mainstream open-source reference (Alarmo) ships countdown chirp/beep orchestration natively despite a 2+ year open request (#910); if OpenCCU-Loom wants this, design it as its own audio-output-driver subsystem — a genuine differentiator, not a port.
  • For multi-area/master-panel arming, adopt Alarmo's "master modes = intersection of all areas" constraint, and design push/actionable notification payloads to carry an area identifier from day one — Alarmo itself cannot target a single area in an actionable notification, a known, still-unaddressed rough edge worth avoiding.
  • For the MQTT alarm_control_panel surface, explicitly decide and document which contract is followed — HA-core's code_arm_required/custom_bypass semantics (arm-scoped code flag, first-class custom-bypass state) versus Alarmo's own bridge semantics (single non-arm-scoped "require code" flag, JSON-embedded code/area) — rather than silently conflating the two, since they differ on whether disarm is separately code-gated.

Sources

ASIR / siren stop semantics

https://homematic-forum.de/forum/viewtopic.php?t=56606 · https://homematic-forum.de/forum/viewtopic.php?t=82178 · https://homematic-forum.de/forum/viewtopic.php?f=58&t=77424 · https://technikkram.net/blog/2020/07/31/quicktipp-ansprechen-einer-hmip-alarmsirene-im-zentralenprogramm/ · https://technikkram.net/blog/2019/06/29/homematic-ip-alarmsirene-aussen-asir-o-endlich-verfuegbar/ · https://community.symcon.de/t/homematic-ip-alarmsirene-schalten-hmip-asir/45005 · https://forum.iobroker.net/topic/38972/steuern-der-hmip-asir-o-sirene · https://forum.iobroker.net/topic/29941/homematic-alarm-sirene-einstellungen-f%C3%BCr-iobroker · https://forum.iobroker.net/topic/66229/homematic-ip-sirene-hmip-asir-auf-laut-oder-still-%C3%A4ndern · https://forum.iobroker.net/topic/7897/gel%C3%B6st-homeatic-ip-alarm-siren-%C3%BCber-script-steuern · https://forum.iobroker.net/topic/14142/gel%C3%B6st-skript-f%C3%BCr-homematic-ip-innensirene · https://github.com/ioBroker/ioBroker.hm-rpc/issues/180 · https://github.com/iobroker-community-adapters/ioBroker.hmip/issues/16 · https://github.com/rdmtc/RedMatic/issues/150 · https://github.com/SukramJ/aiohomematic/discussions/734 · https://www.eq-3.de/downloads/download/homematic_ip/bda/HmIP-ASIR_UM_web.pdf · https://homematic-ip.com/sites/default/files/downloads/hmip-asir-2-um-web.pdf · https://cdn-reichelt.de/documents/datenblatt/E910/HMIP_ASIR-O_ANL-DE.pdf · https://homematic-ip.com/sites/default/files/downloads/hmip-asir-o-153208a0-produktdatenblatt.pdf · https://de.elv.com/p/homematic-ip-smart-home-alarmsirene-hmip-asir-o-aussen-ip44-solarbetrieben-P153208/ · https://de.elv.com/p/homematic-ip-smart-home-alarmsirene-hmip-asir-2-innen-P153825/ · https://www.eq-3.de/downloads/software/firmware/homematic_ip/changelog_HmIP_ASIR_update_V1_0_009_170119.txt · https://www.alarmforum.de/showthread.php?tid=15047 · https://homematic-forum.de/forum/viewtopic.php?t=41251 · https://homematic-forum.de/forum/viewtopic.php?t=76596 · https://homematic-forum.de/forum/viewtopic.php?t=64165 · https://homematic-forum.de/forum/viewtopic.php?t=67947 · https://community.openhab.org/t/solved-hmip-asir-homematic-ip-siren-config-rule-problems/83179 · https://community.home-assistant.io/t/is-homematic-hmip-asir-siren-fully-supported/356693

SWSD smoke-detector sounders

https://homematic-forum.de/forum/viewtopic.php?t=34685 · https://homematic-forum.de/forum/viewtopic.php?t=53206 · https://homematic-forum.de/forum/viewtopic.php?t=56818 · https://homematic-forum.de/forum/viewtopic.php?t=63211 · https://homematic-forum.de/forum/viewtopic.php?t=63503 · https://homematic-forum.de/forum/viewtopic.php?t=75200 · https://homematic-forum.de/forum/viewtopic.php?t=74692 · https://homematic-forum.de/forum/viewtopic.php?t=48050 · https://technikkram.net/blog/2018/03/13/homematic-ip-rauchwarnmelder-hmip-swsd-zusaetzlich-als-alarmsirene-nutzen/ · https://forum.fhem.de/index.php?topic=80462.0 · https://de.elv.com/elvwissen/elvhilft/homematic-sicherheitssteuerung/ · https://de.elv.com/elvwissen/elvhilft/hilfestellungen-zu-homematic-ip-rauchmeldern-und-sicherheitstechnik/ · https://homematic-ip.com/de/produkt/rauchwarnmelder-mit-q-label · https://www.eq-3.de/downloads/download/handbuecher/WebUI_Handbuch_eQ-3.pdf · https://github.com/SukramJ/hahomematic/discussions/955 · https://github.com/SukramJ/hahomematic/discussions/759 · https://community.home-assistant.io/t/homematic-smoke-detector-homematicip-hmip-swsd-service-for-triggering-alarm/152022 · https://community.home-assistant.io/t/homematic-ip-smoke-detector-hip-swsd-setup-binary-alarm-state-sensor-for-integration-in-alarm-panel/674056

WKP keypad

https://homematic-ip.com/sites/default/files/downloads/faq-servicemeldungen-hmip-wkp.pdf · https://homematic-ip.com/sites/default/files/downloads/hmip-wkp-um-web.pdf · https://technikkram.net/blog/2022/05/29/quicktipp-keypad-hmip-wkp-servicemeldungen-zuruecksetzen/ · https://github.com/jens-maus/RaspberryMatic/issues/1846 · https://github.com/jens-maus/RaspberryMatic/issues/2187 · https://github.com/jens-maus/RaspberryMatic/issues/2375 · https://github.com/jens-maus/RaspberryMatic/issues/1567 · https://github.com/eq-3/occu/issues/86 · https://homematic-forum.de/forum/viewtopic.php?t=80009 · https://homematic-forum.de/forum/viewtopic.php?t=74115&start=50 · https://homematic-forum.de/forum/viewtopic.php?t=74115&start=100 · https://homematic-forum.de/forum/viewtopic.php?t=74115&start=120 · https://homematic-forum.de/forum/viewtopic.php?t=83151 · https://homematic-forum.de/forum/viewtopic.php?f=58&t=76808 · https://community.simon42.com/t/alarmo-und-hmip-wkp/32584 · https://community.simon42.com/t/hmip-wkp-von-homematic-einbinden/23363 · https://community.symcon.de/t/erfahrungen-mit-hmip-wkp/129217 · https://forum.iobroker.net/topic/55966/hmip-fwi-code_id-has-value-31-greater-than-max-20 · https://github.com/SukramJ/aiohomematic/issues/1101 · https://github.com/SukramJ/aiohomematic/pull/1102 · https://github.com/SukramJ/homematicip_local/pull/481 · https://github.com/SukramJ/pydevccu/pull/43 · https://raw.githubusercontent.com/SukramJ/pydevccu/master/pydevccu/paramset_descriptions/HmIP-WKP.json · https://raw.githubusercontent.com/SukramJ/pydevccu/master/pydevccu/device_descriptions/HmIP-WKP.json

Alarmo / HmIP app UX

https://homematic-ip.com/sites/default/files/downloads/homematic-ip-anwenderhandbuch.pdf · https://technikkram.net/blog/2019/04/20/kurzerklaerung-hmip-access-point-scharfschalten-basic-scharfschalten-pro/ · https://homematic-forum.de/forum/viewtopic.php?t=46598 · https://homematic-forum.de/forum/viewtopic.php?t=81505 · https://homematic-forum.de/forum/viewtopic.php?t=85128 · https://homematic-forum.de/forum/viewtopic.php?t=41355 · https://github.com/nielsfaber/alarmo/issues/1289 · https://github.com/nielsfaber/alarmo/pull/1345 · https://github.com/nielsfaber/alarmo/issues/1014 · https://github.com/nielsfaber/alarmo/issues/910 · https://github.com/nielsfaber/alarmo/issues/1118 · https://github.com/nielsfaber/alarmo/issues/1308 · https://github.com/nielsfaber/alarmo/issues/1309 · https://github.com/nielsfaber/alarmo/releases · https://github.com/nielsfaber/alarmo/blob/main/README.md · https://www.home-assistant.io/integrations/alarm_control_panel.mqtt/ · https://community.home-assistant.io/t/alarm-system-beep-chirp-sound-suggestions/89283